ricoy288
發表於 2010-10-8 20:08
照睇甘米成組都錯羅.{:6_141:}
lamborghini436
發表於 2010-10-8 20:16
即系點呀, 唔系話第一幅小圖錯咩, 第二幅先冇事咩 {:6_141:}
Netmans
發表於 2010-10-8 20:39
本帖最後由 Netmans 於 2010-10-8 20:54 編輯
即系點呀, 唔系話第一幅小圖錯咩, 第二幅先冇事咩
lamborghini436 發表於 2010-10-8 20:16 http://www.post76.com/discuss/images/common/back.gif
誰 E 文好 d ~~ {:6_140:}
http://www.avforums.com/forums/home-cinema-bargains-discount-codes/1298151-belkin-pureav-home-theater-power-console-pf40-38-87-a-3.html
Is the circuit breaker built into the moulded plug that plugs into the mains? If not, where does it sit in the scheme of the circuit?
If the circuit breaker is internal to the unit and if the only "fault" is the incorrectly wired live/neutral in the plug, then swapping of the live-neutral on the unit terminal block would revert the breaker's position to what it should have been if the plug had been wired correctly in the first place.
.... unless of course my assumptions are wrong!!
http://img837.imageshack.us/img837/9868/ss20100807131351.png
07.08.2010
Peridot says :
The circuit breaker is mounted on the back panel of the unit.
If you look at my first picture above - the mains cable comes in on the far left bottom corner. You can just about see a slightly darker brown wire which is the incoming supply that goes immediately to the circuit breaker. The more easily visible brown wire goes from the circuit breaker to the PCB connection.
http://www.avforums.com/forums/attachments/home-cinema-bargains-discount-codes/193775d1281169029-belkin-pureav-home-theater-power-console-pf40-38-87-internal-wiring-original.jpg
http://www.avforums.com/forums/attachments/home-cinema-bargains-discount-codes/193776d1281169045-belkin-pureav-home-theater-power-console-pf40-38-87-internal-wiring-swapped.jpg
Reversing the connections at the PCB basically means that you are using the blue wire as the Live and the brown wire as the Neutral to match the connections in the moulded plug.
Because the circuit breaker is wired in advance of the PCB connections it remains in the Neutral circuit.
Should there be an Live to Earth fault in something connected to the unit then the circuit breaker will not trip. It is then dependent on the speed of response of the next protective device in the chain to operate to protect the Power Console and the connected equipment/cable.
One risk is that the PCB tracks carrying the mains current to the various internal filters will burn out before any other protective device operates.
Google 翻譯
斷路器安裝在背面板上的單位。
如果你看看我的第一張照片以上 - 進來的電源線在最左下角。你可以看到只是一個稍微深褐色的線是去傳入的供應,立即向斷路器。越容易看到棕線去,從斷路器到PCB的連接。
扭轉連接在PCB基本上意味著你使用的是藍色線為 Live和棕色線為中性,以匹配連接的模塑插頭。
由於斷路器有線提前PCB的連接它仍然在中立的電路。
如果有一個活到接地故障的東西,然後連接到本機斷路器不會跳閘。它是那麼依賴於反應速度保護裝置的下一個鏈中,以保護操作控制台和電源連接的設備 /電纜。
風險之一是,PCB線路電源電流攜帶的各種內部過濾器將燃燒在任何其他保護裝置的運轉。
CKKeung
發表於 2010-10-8 20:50
I don't think we have to worry too much.
As long as we plug the UK 13A plug into our wall socket & check that PF40's sockets on its back have correct polarity is correct will be OK. (用它筆對入去插座右面有燈)
kmb10707
發表於 2010-10-8 22:18
唔係好明,有高手翻譯嗎?
vc113
發表於 2010-10-8 22:55
我都唔明....意思係有機會反相??係個別例子定係全部都咁呢?....聽日去5金shop 買返個13A 線路tester先得{:6_160:}
Netmans
發表於 2010-10-8 23:02
本帖最後由 Netmans 於 2010-10-9 00:03 編輯
各 Ching 重有貨 {:6_175:}
http://ii.alatest.com/product/600x400/8/c/Belkin-PureAV-Home-Theater-Power-Console-PF40-0.jpg
http://www.h2oit.com/productdetail.aspx?PartCode=AP21000UK3M&IID=508596
http://www.cclonline.com/product-info.asp?product_id=52182&tid=gsearch&siteID=TnL5HPStwNw-QOj0ultrjLE2cnWuJIV1Hg
But letter on 21.08.2010
http://www.avforums.com/forums/home-cinema-bargains-discount-codes/1298151-belkin-pureav-home-theater-power-console-pf40-38-87-a-7.html
I've just posted a letter to Belkin in the hope that it may help others get better service, too late for me now. The thrust being:
Belkin have allowed incorrectly assembled and potential unsafe product, AP21000UK3M, to reach UK customers. When the health and safety faults were diagnosed and reported to Belkin, Belkin failed to both respond in a timely manner or to honour their “ replace or repair” warranty and left the problem with end users to resolve.
By investing extra time, effort and expense I and others have managed to resource alternative safe product but ultimately I do not believe that end users should be inconvenienced to this extent or be expected to source their own solution routes when faced with incorrectly assembled and potentially unsafe products that you have allowed to reach the market place.
Google 翻譯
我剛剛發表了一封信,貝爾金,希望它可以幫助別人得到更好的服務,對我來說太晚了。推力是:
貝爾金已使不正確的和潛在的不安全的產品組裝,AP21000UK3M(PF40) ,達到英國客戶。當健康和安全故障進行診斷和報告貝爾,貝爾金既沒有及時回應或履行他們的“更換或修理”保修,離開了這個問題,最終用戶來解決。
通過投資額外的時間,精力和費用,我和其他人的安全管理,對資源的替代產品,但最終我不相信,最終用戶應該感到不便到這種程度也不能期望源自己的解決方案時面臨的路線錯誤和潛在的不安全組裝產品,你必須允許達到市場佔有一席之地。
vc113
發表於 2010-10-8 23:22
回復minimoai
睇過呀, 火線 同其它二條線都冇掉轉
lamborghini436 發表於 2010-10-8 17:09 http://www.post76.com/discuss/images/common/back.gif
ching 點先呢冇掉轉呀~我都想拆呢睇下呀 thx
vc113
發表於 2010-10-8 23:24
回復 537# Netmans
其實係咪得呢個sn:AP21000UK3M(PF40) 先係有問題呢??{:6_141:}
lamborghini436
發表於 2010-10-8 23:27
回復 539# vc113
唔系呀, pf50都有 60就唔知