ohnoohno80
發表於 2010-10-14 00:14
I just buy 1.. tht got three light yellow,green,red..
is't 3 must light up?? mine is 3 oso light up.. is't got any proplem??
Netmans
發表於 2010-10-14 15:24
本帖最後由 Netmans 於 2010-10-14 15:26 編輯
I just buy 1.. tht got three light yellow,green,red..
is't 3 must light up?? mine is 3 oso light up. ...
ohnoohno80 發表於 2010-10-14 00:14 http://www.post76.com/discuss/images/common/back.gif
pdf manual : http://www.belkin.com/support/download/files/P74432-B_Manual.pdf
The PureAV Isolator comes with three Diagnostic Indicators, plus an Amber
Master Switch light. When you plug the unit into a live, 120V AC/60Hz
outlet, these lights let you know that protection is activated and warn of a
power problem before you connect your equipment.
Protection (Yellow)
indicates your surge protection is functioning properly.
Line OK (Green)
indicates line integrity.
Line Fault (Red)
indicates wall outlet in use has existing ground fault, or is
improperly wired.
Protection (Yellow): This light should come on when the unit’s power
switch is turned to the “ON” position. If this light goes out at any time, it
means that your surge protector has “sacrificed itself” to protect your
equipment and should be replaced. Please contact Belkin Corporation for a
free surge protector replacement.
Line OK (Green): This light should also come on when the power switch is
turned on. It shows that 120V AC power is present with no wiring faults
and it is safe to plug and use connected equipment.
Line Fault (Red): If on, this light indicates that a wiring fault has been
detected. This may be the result of a lack of grounding or reversed phases,
among other problems. A qualified electrician should be notified so that
the problem can be corrected before plugging in devices.
將英文翻譯為中文(繁體)
該 PureAV隔離帶有三個診斷指標,再加上一個黃色
主開關燈。當您插入機進入現場,120伏AC/60Hz
插座,這些燈讓你知道,保護被激活,並警告一
電源問題在您連接您的設備。
保護(黃)
顯示您的浪湧保護功能正常。
線確定(綠色)
指示線的完整性。
線路故障(紅色)
表明在牆壁插座的使用現有的地面故障,或者是
佈線不當。
保護(黃色):此燈應該就當機電源
開關打開至“ON”位置。如果此燈熄滅在任何時間,
意味著你的浪湧保護器有“犧牲自己”,以保護您的
設備,應予以更換。請與貝爾金公司為一
浪湧保護器免費更換。
線確定(綠色):此燈時,也應在電源開關
開啟。結果表明,120V交流電源時,沒有接線故障
它是安全的插頭,並用連接的設備。
線路故障(紅色):如果在這個指示燈表示線路故障已一
檢測。這可能是導致缺乏一個接地或倒退階段,
除其他問題。一個合格的電工,以便應通知
該問題可以得到糾正之前,封堵設備。
Please use socket tester to test it (ssp have socket tester)
http://www.screwfix.com/sfd/i/cat/83/p2945783_l.jpg
babuwa
發表於 2010-10-14 15:28
I just buy 1.. tht got three light yellow,green,red..
is't 3 must light up?? mine is 3 oso light up. ...
ohnoohno80 發表於 2010-10-14 00:14 http://www.post76.com/discuss/images/common/back.gif
Remind Ching if it's slightly light up should be normal, since some noise induced the Line fault red LED, If fully light up may be have problem.{:6_210:} {:6_210:}
ohnoohno80
發表於 2010-10-14 15:37
回復 53# babuwa
so means have some light up is ok ah.. there won't be totally off light ah..{:1_259:} Thx ching..
babuwa
發表於 2010-10-14 15:38
本帖最後由 babuwa 於 2010-10-14 15:40 編輯
回復babuwa
so means have some light up is ok ah.. there won't be totally off light ah..{:1_ ...
ohnoohno80 發表於 2010-10-14 15:37 http://www.post76.com/discuss/images/common/back.gif
sometime la. should be normal{:6_166:} {:6_166:}
Ching better change fuse later!!{:6_222:} {:6_222:}
ohnoohno80
發表於 2010-10-14 15:44
回復 52# Netmans
i no have that test plug.. ching.. can use test pen ah..{:6_140:}
Netmans
發表於 2010-10-14 15:51
回復Netmans
i no have that test plug.. ching.. can use test pen ah..
ohnoohno80 發表於 2010-10-14 15:44 http://www.post76.com/discuss/images/common/back.gif
ok !! test pen is use right hand side with light.But I suggest you to buy socket tester for your home (Always use to test). {:6_189:}
minimoai
發表於 2010-10-14 17:32
sometime la. should be normal
Ching better change fuse later!!...
babuwa 發表於 2010-10-14 15:38 http://www.post76.com/discuss/images/common/back.gif
Any suggestion??
orhui
發表於 2010-10-14 17:43
舉腳讚成!
toysonline
發表於 2010-10-14 17:48
回復 20# 690691
師兄:記得出報告,我都想買