billymud 發表於 2013-10-8 17:35

本帖最後由 billymud 於 2013-10-8 17:39 編輯

jojo9326 發表於 2013-10-8 17:27 static/image/common/back.gif
師兄你睇下佢點寫。。下面個gnd
(Post76 Android 手機版送出)

The Yellow-Green ribbon cable means Earth (Safety Ground), according to International Electricity Std.



be connected to IEC or 殼 ! {:1_341:}

jojo9326 發表於 2013-10-8 17:53

billymud 發表於 2013-10-8 18:09

jojo9326 發表於 2013-10-8 17:53 static/image/common/back.gif
唔該ching~
等我7少樣野~XD
另外其他既"0"同gnd我全接去powerboard個大地~


pdf, 正 !
你試7下圖中resistor, 拆走紅色線, 再7電壓觀察, 點?

jojo9326 發表於 2013-10-8 18:18

billymud 發表於 2013-10-8 18:21

jojo9326 發表於 2013-10-8 18:18 static/image/common/back.gif
7 = 測?

你話呢?

billymud 發表於 2013-10-8 18:24

本帖最後由 billymud 於 2013-10-8 18:25 編輯

jojo9326 發表於 2013-10-8 16...電牛既初級地端我應該跟iec頭接殼定係係power board個大地接地~?

refer to schematics, you should note the Chasis Ground , the Safety Ground, the Power Return.
tried to denote it for ur ref.......{:1_253:}

jojo9326 發表於 2013-10-8 18:24

billymud 發表於 2013-10-8 18:27

jojo9326 發表於 2013-10-8 18:24 static/image/common/back.gif
好~放工試左話你知~
not to miss thread #76.

jojo9326 發表於 2013-10-8 18:27

jojo9326 發表於 2013-10-8 20:52

頁: 1 2 3 4 5 6 7 [8] 9 10 11 12 13 14 15 16 17
查看完整版本: 遲來的kit 1

重要聲明:本討論區是以即時上載留言的方式運作,Post76玩樂討論區對所有留言的真實性、完整性及立場等,不負任何法律責任。而一切留言之言論只代表留言者個人意 見,並非本網站之立場,讀者及用戶不應信賴內容,並應自行判斷內容之真實性。於有關情形下,讀者及用戶應尋求專業意見(如涉及醫療、法律或投資等問題)。 由於本討論區受到「即時上載留言」運作方式所規限,故不能完全監察所有留言,若讀者及用戶發現有留言出現問題,請聯絡我們。Post76玩樂討論區有權刪除任何留言及拒絕任何人士上載留言 (刪除前或不會作事先警告及通知 ), 同時亦有不刪除留言的權利,如有任何爭議,管理員擁有最終的詮釋權 。用戶切勿撰寫粗言穢語、誹謗、渲染色情暴力或人身攻擊的言論,敬請自律。本網站保留一切法律權利。權利。